Single-channel COB in an encapsulated 20 mm flexible body, 24 V constant voltage, 300 lm/ft series. One measurement on one sample by an independent laboratory; everything below is that reading.
ProfileFlow 20
Output300 lm/ft
CCT2700 k
Voltage24V DC
CRI95+
Specifications
Colour
CCT
2716 K · Duv -0.0023
Chromaticity
x 0.4546 · y 0.4032
Colour consistency
—
Ra · R9
97.5 · 94.0
Mean R1–R15
96.5
TM-30
Not reported by the laboratory
Output and power
Luminous flux
821 lm per metre
Efficacy
42.84 lm/W
Power
19.16 W per metre at 24 V
Current
0.7985 A per metre
Radiant flux
3.183 W
Spectral content
Not reported by the laboratory
Spectral power distribution
Peak 638.0 nm, 149.1 nm wide at half height.
This is a high-fidelity source, and the numbers behind that claim are here
Ra 97.5 with R9 at 94.0 are all well clear of the 90 CRI / 50 R9 thresholds most architectural specifications set.
Measured output runs below the series nominal
821 lm per metre against 984 lm per metre for a 300 lm/ft series, at 2716 K against a 2700 K target. Size drivers and runs on the nominal figure; this is one measurement of one sample, not a production tolerance.
Measured on a one-metre sample at 24 V in an integrating sphere by an independent laboratory. Fast-scan mode, high sensitivity, source cooling on. Date 2026-04-30, 25.6 °C and 65.0% RH.
Spectral data summary · full data
Flow 20 · 2700 K
Every value the laboratory reported. Page 1 is drawn from this page and nothing else.
Colour rendering by sample, R1–R15
Ra 97.5 (mean of R1–R8) · mean R1–R15 96.5
Bar heights are the measurement. Each bar is tinted with the Munsell notation CIE 13.3 gives its own test sample; the colours only name the sample. R9 and R12 are more saturated than a screen or a press can show and have been pulled into range.
Sample
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
CIE 13.3
98
98
98
98
98
96
97
97
94
98
95
87
97
98
99
Full measured parameters
Chromaticity x, y
0.4546, 0.4032
Chromaticity u′, v′
0.2624, 0.5237
CCT
2716 K
Duv
-0.0023
SDCM
—
Dominant wavelength
584.9 nm
Colour purity
57.5%
Peak wavelength
638.0 nm
Spectral FWHM
149.1 nm
Centroid wavelength
Not reported
Luminous flux
821 lm
Luminous efficacy
42.84 lm/W
Radiant flux
3.183 W
Voltage
24.000 V
Current
0.7985 A
Power
19.16 W
Power factor
1.000
Spectral content
Not reported
Date
2026-04-30
Ambient
25.6 °C · 65.0% RH
Measured point against the Planckian locus
Plotted in CIE 1960 uv with both axes at the same scale, so the gap between the point and the curve is the Duv itself. Locus from the Kim et al. cubic approximation. The point sits 0.0023 below the curve — around 0.2 of the 0.010 at which a departure from the locus starts to be noticed as a tint.
Transcribed by Alkimi from the laboratory report. The spectral curve is redrawn from the plot on that report; it integrates to within 0.2% of the radiant flux the report states separately, which is the check on the redraw. Laboratory name, instrument model and the manufacturer’s internal part numbers are withheld here and available on request.