Single-channel COB on a 10 mm flexible carrier, 24 V constant voltage, 300 lm/ft series. One measurement on one sample by an independent laboratory; everything below is that reading.
ProfileRimi 10
Output300 lm/ft
CCT2400 k
Voltage24V DC
CRI95+
Specifications
Colour
CCT
2392 K · Duv +0.0011
Chromaticity
x 0.4892 · y 0.4182
Colour consistency
2.8 SDCM
Ra · R9
97.4 · 79.2
Mean R1–R15
95.9
TM-30
Rf 95 · Rg 98
Output and power
Luminous flux
1049 lm per metre
Efficacy
90.50 lm/W
Power
11.59 W per metre at 24 V
Current
0.4829 A per metre
Radiant flux
4.106 W
Spectral content
R 30.0% · G 67.9% · B 2.1%
Spectral power distribution
Peak 634.0 nm, 125.8 nm wide at half height, centroid 621.4 nm. Only 2.1% of the radiated power sits in the blue band — the signature of a warm, deeply phosphor-converted source.
This is a high-fidelity source, and the numbers behind that claim are here
Ra 97.4 with R9 at 79.2 and a TM-30 fidelity of 95 are all well clear of the 90 CRI / 50 R9 thresholds most architectural specifications set. Rg 98 means saturation is held close to the reference rather than pushed, so colours read natural rather than enhanced.
Measured output runs above the series nominal
1049 lm per metre against 984 lm per metre for a 300 lm/ft series, at 2392 K against a 2400 K target. Size drivers and runs on the nominal figure; this is one measurement of one sample, not a production tolerance.
Measured on a one-metre sample at 24 V in an integrating sphere by an independent laboratory. Fast-scan mode, high sensitivity, source cooling on. Date 2026-04-07, 25.3 °C and 35.0% RH.
Spectral data summary · full data
Rimi 10 · 2400 K
Every value the laboratory reported. Page 1 is drawn from this page and nothing else.
Colour rendering by sample, R1–R15
Ra 97.4 (mean of R1–R8) · mean R1–R15 95.9 · TM-30 Rf 95, Rg 98
Bar heights are the measurement. Each bar is tinted with the Munsell notation CIE 13.3 gives its own test sample; the colours only name the sample. R9 and R12 are more saturated than a screen or a press can show and have been pulled into range.
Sample
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
CIE 13.3
99.5
99.7
99.1
98.9
99.7
96.3
95.3
90.6
79.2
99.3
94.6
93.7
99.7
98.3
95
GB/T 5702
100
94
85
99
100
96
90
95
97
89
101
91
100
91
98
The second row is the Chinese national standard’s own sample set, reported alongside: Ra 95, gamut Ga 0.99. It is a different set of test colours, not a second opinion on the first row.
Full measured parameters
Chromaticity x, y
0.4892, 0.4182
Chromaticity u′, v′
0.2779, 0.5346
CCT
2392 K
Duv
+0.0011
SDCM
2.8
Dominant wavelength
585.6 nm
Colour purity
72.4%
Peak wavelength
634.0 nm
Spectral FWHM
125.8 nm
Centroid wavelength
621.4 nm
Luminous flux
1049 lm
Luminous efficacy
90.50 lm/W
Radiant flux
4.106 W
Voltage
23.997 V
Current
0.4829 A
Power
11.59 W
Power factor
1.000
Spectral content
R 30.02% · G 67.90% · B 2.08%
Date
2026-04-07
Ambient
25.3 °C · 35.0% RH
Measured point against the Planckian locus
Plotted in CIE 1960 uv with both axes at the same scale, so the gap between the point and the curve is the Duv itself. Locus from the Kim et al. cubic approximation. The point sits 0.0011 above the curve — around 0.1 of the 0.010 at which a departure from the locus starts to be noticed as a tint, and consistent with the 2.8 SDCM reading.
Transcribed by Alkimi from the laboratory report. The spectral curve is redrawn from the plot on that report; it integrates to within 0.2% of the radiant flux the report states separately, which is the check on the redraw. Laboratory name, instrument model and the manufacturer’s internal part numbers are withheld here and available on request.