Single-channel COB on a 10 mm flexible carrier, 24 V constant voltage, 600 lm/ft series. One measurement on one sample by an independent laboratory; everything below is that reading.
ProfileRimi 10
Output600 lm/ft
CCT2400 k
Voltage24V DC
CRI95+
Specifications
Colour
CCT
2473 K · Duv +0.0052
Chromaticity
x 0.4898 · y 0.4308
Colour consistency
6.5 SDCM
Ra · R9
95.2 · 65.8
Mean R1–R15
93.2
TM-30
Rf 88 · Rg 92
Output and power
Luminous flux
2223 lm per metre
Efficacy
121.54 lm/W
Power
18.29 W per metre at 24 V
Current
0.7622 A per metre
Radiant flux
6.862 W
Spectral content
R 29.6% · G 68.4% · B 2.0%
Spectral power distribution
Peak 632.3 nm, 10.0 nm wide at half height, centroid 604.7 nm. That red peak is a narrow line standing on the broad conversion band, not a phosphor shoulder; this sample reads 122 lm/W with R9 at 65.8. Only 2.0% of the radiated power sits in the blue band — the signature of a warm, deeply phosphor-converted source.
Where this sample sits against the usual specification thresholds
Ra 95.2 with R9 at 65.8 and a TM-30 fidelity of 88 sit against the 90 CRI / 50 R9 thresholds most architectural specifications set. Rg 92 means saturation is below the reference, so saturated colours read a little flatter than the reference renders them.
Measured output runs above the series nominal
2223 lm per metre against 1969 lm per metre for a 600 lm/ft series, at 2473 K against a 2400 K target. Size drivers and runs on the nominal figure; this is one measurement of one sample, not a production tolerance.
Measured on a one-metre sample at 24 V in an integrating sphere by an independent laboratory. Fast-scan mode, high sensitivity, source cooling on. Date 2026-04-22, 25.3 °C and 35.0% RH.
Spectral data summary · full data
Rimi 10 · 2400 K
Every value the laboratory reported. Page 1 is drawn from this page and nothing else.
Colour rendering by sample, R1–R15
Ra 95.2 (mean of R1–R8) · mean R1–R15 93.2 · TM-30 Rf 88, Rg 92
Bar heights are the measurement. Each bar is tinted with the Munsell notation CIE 13.3 gives its own test sample; the colours only name the sample. R9 and R12 are more saturated than a screen or a press can show and have been pulled into range.
Sample
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
CIE 13.3
99.4
98.1
96.8
95.6
99.1
94.5
92.8
85.5
65.8
95.8
91.1
96.7
98.8
97.1
91.3
GB/T 5702
103
93
73
96
98
98
96
96
95
85
100
89
103
81
98
The second row is the Chinese national standard’s own sample set, reported alongside: Ra 81, gamut Ga 0.92. It is a different set of test colours, not a second opinion on the first row.
Full measured parameters
Chromaticity x, y
0.4898, 0.4308
Chromaticity u′, v′
0.2725, 0.5393
CCT
2473 K
Duv
+0.0052
SDCM
6.5
Dominant wavelength
584.0 nm
Colour purity
76.4%
Peak wavelength
632.3 nm
Spectral FWHM
10.0 nm
Centroid wavelength
604.7 nm
Luminous flux
2223 lm
Luminous efficacy
121.54 lm/W
Radiant flux
6.862 W
Voltage
23.997 V
Current
0.7622 A
Power
18.29 W
Power factor
1.000
Spectral content
R 29.55% · G 68.40% · B 2.05%
Date
2026-04-22
Ambient
25.3 °C · 35.0% RH
Measured point against the Planckian locus
Plotted in CIE 1960 uv with both axes at the same scale, so the gap between the point and the curve is the Duv itself. Locus from the Kim et al. cubic approximation. The point sits 0.0052 above the curve — around 0.5 of the 0.010 at which a departure from the locus starts to be noticed as a tint, and consistent with the 6.5 SDCM reading.
Transcribed by Alkimi from the laboratory report. The spectral curve is redrawn from the plot on that report; it integrates to within 0.5% of the radiant flux the report states separately, which is the check on the redraw. Laboratory name, instrument model and the manufacturer’s internal part numbers are withheld here and available on request.