Single-channel COB on a 10 mm flexible carrier, 24 V constant voltage, 900 lm/ft series. One measurement on one sample by an independent laboratory; everything below is that reading.
ProfileRimi 10
Output900 lm/ft
CCT2700 k
Voltage24V DC
Specifications
Colour
CCT
2780 K · Duv +0.0013
Chromaticity
x 0.4532 · y 0.4123
Colour consistency
—
Ra · R9
94.3 · 70.0
Mean R1–R15
91.6
TM-30
Rf 92 · Rg 99
Output and power
Luminous flux
3066 lm per metre
Efficacy
123.65 lm/W
Power
24.79 W per metre at 24 V
Current
1.0330 A per metre
Radiant flux
11.056 W
Spectral content
R 25.7% · G 71.8% · B 2.6%
Spectral power distribution
Peak 628.0 nm, 158.8 nm wide at half height. Only 2.6% of the radiated power sits in the blue band — the signature of a warm, deeply phosphor-converted source.
This is a high-fidelity source, and the numbers behind that claim are here
Ra 94.3 with R9 at 70.0 and a TM-30 fidelity of 92 are all well clear of the 90 CRI / 50 R9 thresholds most architectural specifications set. Rg 99 means saturation is held close to the reference rather than pushed, so colours read natural rather than enhanced.
Measured output runs above the series nominal
3066 lm per metre against 2953 lm per metre for a 900 lm/ft series, at 2780 K against a 2700 K target. Size drivers and runs on the nominal figure; this is one measurement of one sample, not a production tolerance.
Measured on a one-metre sample at 24 V in an integrating sphere by an independent laboratory. Fast-scan mode, high sensitivity, source cooling on. Date 2026-04-14, 25.3 °C and 65.0% RH.
Spectral data summary · full data
Rimi 10 · 2700 K
Every value the laboratory reported. Page 1 is drawn from this page and nothing else.
Colour rendering by sample, R1–R15
Ra 94.3 (mean of R1–R8) · mean R1–R15 91.6 · TM-30 Rf 92, Rg 99
Bar heights are the measurement. Each bar is tinted with the Munsell notation CIE 13.3 gives its own test sample; the colours only name the sample. R9 and R12 are more saturated than a screen or a press can show and have been pulled into range.
Sample
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
CIE 13.3
95
97
98
94
94
96
94
86
70
92
95
79
95
98
91
Full measured parameters
Chromaticity x, y
0.4532, 0.4123
Chromaticity u′, v′
0.2574, 0.5270
CCT
2780 K
Duv
+0.0013
SDCM
—
Dominant wavelength
583.3 nm
Colour purity
59.8%
Peak wavelength
628.0 nm
Spectral FWHM
158.8 nm
Centroid wavelength
Not reported
Luminous flux
3066 lm
Luminous efficacy
123.65 lm/W
Radiant flux
11.056 W
Voltage
24.000 V
Current
1.0330 A
Power
24.79 W
Power factor
1.000
Spectral content
R 25.70% · G 71.80% · B 2.60%
Date
2026-04-14
Ambient
25.3 °C · 65.0% RH
Measured point against the Planckian locus
Plotted in CIE 1960 uv with both axes at the same scale, so the gap between the point and the curve is the Duv itself. Locus from the Kim et al. cubic approximation. The point sits 0.0013 above the curve — around 0.1 of the 0.010 at which a departure from the locus starts to be noticed as a tint.
Transcribed by Alkimi from the laboratory report. The spectral curve is redrawn from the plot on that report; it integrates to within 0.2% of the radiant flux the report states separately, which is the check on the redraw. Laboratory name, instrument model and the manufacturer’s internal part numbers are withheld here and available on request.