Spectral data summary
Rimi 10 · 2700 K
Single-channel COB on a 10 mm flexible carrier, 24 V constant voltage, 900 lm/ft series. One measurement on one sample by an independent laboratory; everything below is that reading.
ProfileRimi 10
Output900 lm/ft
CCT2700 k
Voltage24V DC

Specifications

Colour

CCT2780 K · Duv +0.0013
Chromaticityx 0.4532 · y 0.4123
Colour consistency—
Ra · R994.3 · 70.0
Mean R1–R1591.6
TM-30Rf 92 · Rg 99

Output and power

Luminous flux3066 lm per metre
Efficacy123.65 lm/W
Power24.79 W per metre at 24 V
Current1.0330 A per metre
Radiant flux11.056 W
Spectral contentR 25.7% · G 71.8% · B 2.6%

Spectral power distribution

2550400450500550600650700750mW/nmnm
Peak 628.0 nm, 158.8 nm wide at half height. Only 2.6% of the radiated power sits in the blue band — the signature of a warm, deeply phosphor-converted source.
This is a high-fidelity source, and the numbers behind that claim are here
Ra 94.3 with R9 at 70.0 and a TM-30 fidelity of 92 are all well clear of the 90 CRI / 50 R9 thresholds most architectural specifications set. Rg 99 means saturation is held close to the reference rather than pushed, so colours read natural rather than enhanced.
Measured output runs above the series nominal
3066 lm per metre against 2953 lm per metre for a 900 lm/ft series, at 2780 K against a 2700 K target. Size drivers and runs on the nominal figure; this is one measurement of one sample, not a production tolerance.
Measured on a one-metre sample at 24 V in an integrating sphere by an independent laboratory. Fast-scan mode, high sensitivity, source cooling on. Date 2026-04-14, 25.3 °C and 65.0% RH.
Spectral data summary · full data
Rimi 10 · 2700 K
Every value the laboratory reported. Page 1 is drawn from this page and nothing else.

Colour rendering by sample, R1–R15

Ra 94.3 (mean of R1–R8) · mean R1–R15 91.6 · TM-30 Rf 92, Rg 99
508010090R1R2R3R4R5R6R7R8R970.0R10R11R12R13R14R15
Bar heights are the measurement. Each bar is tinted with the Munsell notation CIE 13.3 gives its own test sample; the colours only name the sample. R9 and R12 are more saturated than a screen or a press can show and have been pulled into range.
SampleR1R2R3R4R5R6R7R8R9R10R11R12R13R14R15
CIE 13.3959798949496948670929579959891

Full measured parameters

Chromaticity x, y0.4532, 0.4123
Chromaticity u′, v′0.2574, 0.5270
CCT2780 K
Duv+0.0013
SDCM—
Dominant wavelength583.3 nm
Colour purity59.8%
Peak wavelength628.0 nm
Spectral FWHM158.8 nm
Centroid wavelengthNot reported
Luminous flux3066 lm
Luminous efficacy123.65 lm/W
Radiant flux11.056 W
Voltage24.000 V
Current1.0330 A
Power24.79 W
Power factor1.000
Spectral contentR 25.70% · G 71.80% · B 2.60%
Date2026-04-14
Ambient25.3 °C · 65.0% RH

Measured point against the Planckian locus

0.200.220.240.260.280.300.320.340.350.362000K3000K3500K4000K2780 K · Duv +0.0013Measured pointCIE 1960 vCIE 1960 u
Plotted in CIE 1960 uv with both axes at the same scale, so the gap between the point and the curve is the Duv itself. Locus from the Kim et al. cubic approximation. The point sits 0.0013 above the curve — around 0.1 of the 0.010 at which a departure from the locus starts to be noticed as a tint.
Transcribed by Alkimi from the laboratory report. The spectral curve is redrawn from the plot on that report; it integrates to within 0.2% of the radiant flux the report states separately, which is the check on the redraw. Laboratory name, instrument model and the manufacturer’s internal part numbers are withheld here and available on request.