Spectral data summary
Rimi 10 · 3500 K
Single-channel COB on a 10 mm flexible carrier, 24 V constant voltage, 300 lm/ft series. One measurement on one sample by an independent laboratory; everything below is that reading.
ProfileRimi 10
Output300 lm/ft
CCT3500 k
Voltage24V DC
CRI95+

Specifications

Colour

CCT3471 K · Duv -0.0016
Chromaticityx 0.4053 · y 0.3871
Colour consistency1.7 SDCM
Ra · R997.4 · 87.6
Mean R1–R1595.7
TM-30Rf 95 · Rg 102

Output and power

Luminous flux1321 lm per metre
Efficacy116.42 lm/W
Power11.35 W per metre at 24 V
Current0.4728 A per metre
Radiant flux4.810 W
Spectral contentR 22.5% · G 73.8% · B 3.7%

Spectral power distribution

81624400450500550600650700750mW/nmnm
Peak 630.1 nm, 186.6 nm wide at half height, centroid 594.9 nm. 3.7% of the radiated power sits in the blue band, the modest share a 3500 K phosphor conversion leaves of its own pump.
This is a high-fidelity source, and the numbers behind that claim are here
Ra 97.4 with R9 at 87.6 and a TM-30 fidelity of 95 are all well clear of the 90 CRI / 50 R9 thresholds most architectural specifications set. Rg 102 means saturation is held close to the reference rather than pushed, so colours read natural rather than enhanced.
Measured output runs above the series nominal
1321 lm per metre against 984 lm per metre for a 300 lm/ft series, at 3471 K against a 3500 K target. Size drivers and runs on the nominal figure; this is one measurement of one sample, not a production tolerance.
Measured on a one-metre sample at 24 V in an integrating sphere by an independent laboratory. Fast-scan mode, high sensitivity, source cooling on. Date 2026-03-30, 25.3 °C and 35.0% RH.
Spectral data summary · full data
Rimi 10 · 3500 K
Every value the laboratory reported. Page 1 is drawn from this page and nothing else.

Colour rendering by sample, R1–R15

Ra 97.4 (mean of R1–R8) · mean R1–R15 95.7 · TM-30 Rf 95, Rg 102
508010090R1R2R3R4R5R6R7R8R9R10R11R1281.7R13R14R15
Bar heights are the measurement. Each bar is tinted with the Munsell notation CIE 13.3 gives its own test sample; the colours only name the sample. R9 and R12 are more saturated than a screen or a press can show and have been pulled into range.
SampleR1R2R3R4R5R6R7R8R9R10R11R12R13R14R15
CIE 13.398.998.896.698.298.496.597.39587.695.896.681.799.497.497.7
GB/T 570298857998100837292988010082958397
The second row is the Chinese national standard’s own sample set, reported alongside: Ra 93, gamut Ga 1. It is a different set of test colours, not a second opinion on the first row.

Full measured parameters

Chromaticity x, y0.4053, 0.3871
Chromaticity u′, v′0.2372, 0.5098
CCT3471 K
Duv-0.0016
SDCM1.7
Dominant wavelength581.7 nm
Colour purity37.8%
Peak wavelength630.1 nm
Spectral FWHM186.6 nm
Centroid wavelength594.9 nm
Luminous flux1321 lm
Luminous efficacy116.42 lm/W
Radiant flux4.810 W
Voltage23.997 V
Current0.4728 A
Power11.35 W
Power factor1.000
Spectral contentR 22.47% · G 73.84% · B 3.69%
Date2026-03-30
Ambient25.3 °C · 35.0% RH

Measured point against the Planckian locus

0.200.220.240.260.280.300.320.340.350.362000K3000K3500K4000K3471 K · Duv -0.0016Measured pointCIE 1960 vCIE 1960 u
Plotted in CIE 1960 uv with both axes at the same scale, so the gap between the point and the curve is the Duv itself. Locus from the Kim et al. cubic approximation. The point sits 0.0016 below the curve — around 0.2 of the 0.010 at which a departure from the locus starts to be noticed as a tint, and consistent with the 1.7 SDCM reading.
Transcribed by Alkimi from the laboratory report. The spectral curve is redrawn from the plot on that report; it integrates to within 0.1% of the radiant flux the report states separately, which is the check on the redraw. Laboratory name, instrument model and the manufacturer’s internal part numbers are withheld here and available on request.