Spectral data summary
Rimi 10 · 3500 K
Single-channel COB on a 10 mm flexible carrier, 24 V constant voltage, 600 lm/ft series. One measurement on one sample by an independent laboratory; everything below is that reading.
ProfileRimi 10
Output600 lm/ft
CCT3500 k
Voltage24V DC
CRI95+

Specifications

Colour

CCT3491 K · Duv +0.0007
Chromaticityx 0.4065 · y 0.3929
Colour consistency1.0 SDCM
Ra · R997.4 · 82.4
Mean R1–R1595.4
TM-30Rf 94 · Rg 101

Output and power

Luminous flux2348 lm per metre
Efficacy131.70 lm/W
Power17.83 W per metre at 24 V
Current0.7429 A per metre
Radiant flux7.342 W
Spectral contentR 22.9% · G 73.4% · B 3.7%

Spectral power distribution

306090400450500550600650700750mW/nmnm
Peak 632.3 nm, 10.2 nm wide at half height, centroid 578.2 nm. That red peak is a narrow line standing on the broad conversion band, not a phosphor shoulder; this sample reads 132 lm/W with R9 at 82.4. 3.7% of the radiated power sits in the blue band, the modest share a 3500 K phosphor conversion leaves of its own pump.
This is a high-fidelity source, and the numbers behind that claim are here
Ra 97.4 with R9 at 82.4 and a TM-30 fidelity of 94 are all well clear of the 90 CRI / 50 R9 thresholds most architectural specifications set. Rg 101 means saturation is held close to the reference rather than pushed, so colours read natural rather than enhanced.
Measured output runs above the series nominal
2348 lm per metre against 1969 lm per metre for a 600 lm/ft series, at 3491 K against a 3500 K target. Size drivers and runs on the nominal figure; this is one measurement of one sample, not a production tolerance.
Measured on a one-metre sample at 24 V in an integrating sphere by an independent laboratory. Fast-scan mode, high sensitivity, source cooling on. Date 2026-04-16, 25.3 °C and 35.0% RH.
Spectral data summary · full data
Rimi 10 · 3500 K
Every value the laboratory reported. Page 1 is drawn from this page and nothing else.

Colour rendering by sample, R1–R15

Ra 97.4 (mean of R1–R8) · mean R1–R15 95.4 · TM-30 Rf 94, Rg 101
508010090R1R2R3R4R5R6R7R8R982.4R10R11R12R13R14R15
Bar heights are the measurement. Each bar is tinted with the Munsell notation CIE 13.3 gives its own test sample; the colours only name the sample. R9 and R12 are more saturated than a screen or a press can show and have been pulled into range.
SampleR1R2R3R4R5R6R7R8R9R10R11R12R13R14R15
CIE 13.398.899.696.997.699.496.696.793.582.497.593.985.299.297.197.2
GB/T 570210184729698847794977910082977698
The second row is the Chinese national standard’s own sample set, reported alongside: Ra 97, gamut Ga 1. It is a different set of test colours, not a second opinion on the first row.

Full measured parameters

Chromaticity x, y0.4065, 0.3929
Chromaticity u′, v′0.2356, 0.5124
CCT3491 K
Duv+0.0007
SDCM1.0
Dominant wavelength580.6 nm
Colour purity39.9%
Peak wavelength632.3 nm
Spectral FWHM10.2 nm
Centroid wavelength578.2 nm
Luminous flux2348 lm
Luminous efficacy131.70 lm/W
Radiant flux7.342 W
Voltage23.997 V
Current0.7429 A
Power17.83 W
Power factor1.000
Spectral contentR 22.89% · G 73.39% · B 3.72%
Date2026-04-16
Ambient25.3 °C · 35.0% RH

Measured point against the Planckian locus

0.200.220.240.260.280.300.320.340.350.362000K3000K3500K4000K3491 K · Duv +0.0007Measured pointCIE 1960 vCIE 1960 u
Plotted in CIE 1960 uv with both axes at the same scale, so the gap between the point and the curve is the Duv itself. Locus from the Kim et al. cubic approximation. The point sits 0.0007 above the curve — around 0.1 of the 0.010 at which a departure from the locus starts to be noticed as a tint, and consistent with the 1.0 SDCM reading.
Transcribed by Alkimi from the laboratory report. The spectral curve is redrawn from the plot on that report; it integrates to within 0.4% of the radiant flux the report states separately, which is the check on the redraw. Laboratory name, instrument model and the manufacturer’s internal part numbers are withheld here and available on request.